Change-Over Return Line Filter - Tank Mounted - RFD

POA

The HYDAC RFD filter series is a return line filter. It has a flow capacity up to 1300 l/min and a pressure capacity up to 25 bar.

The design of the filter housings is in accordance with international regulations. They consist of one-piece housings with bolt-on cover plates.

What's more, the connection of the two housings happens by a ball change-over valve with negative overlap and single-lever operation.

Standard equipment:

  • Bypass valve
  • Connection for a clogging indicator (1 clogging indicator per filter side!)
Specifications:
  • Flow rates up to 1300 l/min
  • Pressure levels up to 25 bar
  • Connections: G¾ to SAE DN 100
  • Installation sizes: 60, 110, 160, 240, 330, 660, 950, 1300
 Filter elements: Click here.Clogging Indicator: Click here.Seal & Repair Kits: Click here.
Filter-IT²

Filter-IT²

Product 
ChangeOver Return Line Filter Tank Mounted RFD

Please contact the store to confirm stock availability near you

Recommended Products

FAQs

  • What is a return line filter?

    A return line filter performs the task of filtering fluid and preventing particles from entering the system externally or from internal wear and tear of components. 

    What characterises the change-over return line filter – RFD?

    A ‘change-over’ characterises the change-over return line filter – RFD, which closes one circuit and simultaneously opens a second circuit, thereby fulfilling the function of a ‘normally open’ and ‘normally closed’ contact. This means that, in operation, a change-over can only ever have one connected circuit closed and one energised.

    What is the change-over return line filter – RFD’s flow capacity?

    The change-over return line filter – RFD’s flow capacity is 1300L/min.

    What is the change-over return line filter – RFD’s pressure capacity?

    The change-over return line filter – RFD’s pressure capacity is up to 25 bar.

    What comprises the change-over return line filter – RFD’s filter housings?

    The change-over return line filter – RFD’s filter housings consist of one-piece housings with bolt-on cover plates. The two housings are connected by a ball change-over valve with negative overlap and single-lever operation. Standard equipment includes a bypass valve and connections for a clogging indicator per filter side.

    What are change-over return line filter – RFD’s connections?

    Change-over return line filter – RFD’s connections span G¾ to SAE DN 100.

    What are change-over return line filter – RFD’s installation sizes?

    Change-over return line filter – RFD installation sizes are 60, 110, 160, 240, 330, 660, 950, 1300.